The Cleverscope CS328A was configured for Frequency Response Analysis (FRA) of the TI TPS55340 flyback converter EVM by injecting a small AC signal across a modified 50Ω resistor in the feedback path. The setup includes:
-
Signal injection via Jensen VB-1BB transformer
-
Sweep range from 7.6 Hz to 200 kHz
-
Excitation voltage: ~11–13 mV peak, optimized adaptively
-
Channel A (TP6) reads the injected signal
-
Channel B (TP2) captures the power supply’s response
-
Signal coherence and gain/phase measured using the Cleverscope FRA application (v4.672)
The system proved to be highly accurate, delivering phase margins around 60° and gain margins up to -19 dB, depending on line/load conditions. These results were validated against both TI's own analysis and Venable equipment.