| Compatible Device |
Cleverscope CS328A, TI TPS55340EVM |
| Signal Injection |
10 mV peak excitation (via Jensen VB-1BB transformer) |
| Frequency Range |
20 Hz to 200 kHz |
| Measurement Method |
Gain/Phase Response with Narrow Band Correlation |
| Phase Margin (PM) |
45° to 70° for optimal stability |
| Gain Margin (GM) |
-13 dB tolerance before instability |
| Test Signal Method |
Sweep with 20 steps per decade |
| Measurement Device |
14-bit ADC with 1.28 µs moving average filter |
| Low Frequency Boost |
Adaptive, ensures accurate low-frequency response |
| Voltage Range |
12V (Nominal), 8V (Low-line), 24V (High-line) |
| Load Conditions |
2.5A and 1A for different scenarios |
| Response Time |
0.5 Hz to 200 kHz |